Aegis › The Physics
The Physics

Honest Gate: Plug Coil Overstress

At the design bore the 26.49 T plug coil is overstressed by roughly 3 to 3.9 times — infeasible as specified. This is a physics fact, stated plainly.

The gate, stated at full strength

The burner's end plugs require a 26.49 T field. At the design bore, the plug coil is overstressed by roughly 3 to 3.9 times what the conductor and its structure can bear as specified. In its current form the plug magnet is infeasible. We state this plainly because it is a physics-and-engineering fact, not a matter of optimism.

limit 1×3.9×stress at the design borecoil stress

The cause is fundamental: magnetic pressure scales as B2, so a 26.49 T coil carries an enormous outward force that its winding and support structure must react. At the specified bore, no available conductor-and-structure combination keeps the stress within allowables by a factor of three to nearly four.

Why we do not soften it

The confining potential the burner needs requires this field; the field at this bore breaks the coil. Resolving the gap — through geometry, materials, or field-shaping — is open work, and until it closes the burner remains a design-and-simulation study. Stating the 3–3.9× overstress honestly is what makes the rest of the design trustworthy.

Nothing about the gate is hidden in an assumption: it follows directly from the specified field and bore and the strength of real conductor and structure. Closing it is legitimate future work — through field-shaping, graded coils, advanced conductors, or a revised geometry — but until a concrete design holds the stress within allowables, the honest statement is that the plug magnet, as specified, does not close.

Content reviewed August 2026 · design-and-simulation stage